SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
427
2 Parameters
2.2 List of parameters
Description:
Sets the damping of a PT2 element for the reference model of the speed controller.
Recommendation:
The reference model is correctly set when the characteristics of r52154 (reference model output) and r52167 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency:
In conjunction with p50237 and p50239, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
Refer to: p50237, p50239
Description:
Sets the "fractional" dead time for the reference model of the speed controller.
This parameter emulates the computing dead time of the proportionally controlled speed control loop.
The multiplier set refers to the speed controller clock cycle.
Recommendation:
The reference model is correctly set when the characteristics of r52154 (reference model output) and r52167 (actual
speed value) are virtually identical when the I component of the speed controller is disabled.
Dependency:
In conjunction with p50237 and p50238, the characteristics (in time) of the P-controlled speed control loop can be
emulated.
Refer to: p50237, p50238
Description:
Setting to activate the influence of the reference model for the speed controller.
Value:
0:
Reference model not effective
1:
Reference model effective
Dependency:
Refer to: p50241
Description:
Sets the signal source for the input signal of the reference model for the speed controller.
Dependency:
Refer to: p50240
p50238[0...n]
Speed controller reference model damping / n_ctrl ref_m d
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6812
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.000 5.000
1.000
p50239[0...n]
Speed controller reference model dead time / n_ctr ref_m t_dead
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6812
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 2.00
0.00
p50240[0...n]
Speed controller reference model activation / n_ctrl ref_m act
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
DDS, p0180
Func. diagram:
6815
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0
p50241
CI: Speed controller reference model signal source / n_ctrl ref_m sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / FloatingPoint32
Dyn. index:
-
Func. diagram:
6815
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- -
52155[0]