2 Parameters
2.2 List of parameters
Value:
0:
Deactivated
1:
Activated
Dependency:
Refer to: p50284
Note:
If value = 0:
The integral component of the EMF controller is kept constantly at zero (i.e. the EMF controller functions solely as a
proportional controller).
Description:
Sets the P gain of the EMF controller.
Dependency:
Refer to: p50276
Note:
The parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Description:
Sets the integral time of the EMF controller.
Dependency:
Refer to: p50275
Note:
The parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Description:
Sets the value for the EMF controller's droop feedback.
Note:
If value = 0:
Droop feedback is de-activated.
Description:
Sets the smoothing time constant for the setpoint for EMF controller pre-control.
Dependency:
Refer to: p50283
Note:
This smoothing enables the EMF controller pre-control to be decoupled from the EMF controller.
p50275[0...n]
EMF controller P gain / EMF ctr Kp
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.01 100.00
0.60
p50276[0...n]
EMF controller integral time / EMF ctr Tn
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.010 [s]
10.000 [s]
0.200 [s]
p50277[0...n]
EMF controller droop / EMF ctr droop
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
10.0 [%]
0.0 [%]
p50280[0...n]
EMF controller pre-control setpoint smoothing time constant / EMF prec set T
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 [ms]
10000 [ms]
0 [ms]