SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
405
2 Parameters
2.2 List of parameters
Description:
Setting of the field current for a motor flux of 20 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50123 and less than p50125 can be set.
Description:
Setting of the field current for a motor flux of 25 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50124 and less than p50126 can be set.
Description:
Setting of the field current for a motor flux of 30 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50125 and less than p50127 can be set.
Description:
Setting of the field current for a motor flux of 35 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50126 and less than p50128 can be set.
p50124[0...n]
Field current for motor flux 20 % / I_field flux 20%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
14.7 [%]
p50125[0...n]
Field current for motor flux 25 % / I_field flux 25%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
18.4 [%]
p50126[0...n]
Field current for motor flux 30 % / I_field flux 30%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
22.0 [%]
p50127[0...n]
Field current for motor flux 35 % / I_field flux 35%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
25.7 [%]