2 Parameters
2.2 List of parameters
SINAMICS DCM
404
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Setting of the field current for a motor flux of 0 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values less than p50121 can be set.
Description:
Setting of the field current for a motor flux of 5 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50120 and less than p50122 can be set.
Description:
Setting of the field current for a motor flux of 10 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50121 and less than p50123 can be set.
Description:
Setting of the field current for a motor flux of 15 %.
Note:
This parameter is set automatically during the optimization run for field weakening (p50051 = 27).
Only values greater than p50122 and less than p50124 can be set.
p50120[0...n]
Field current for motor flux 0 % / I_field flux 0%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
0.0 [%]
p50121[0...n]
Field current for motor flux 5 % / I_field flux 5%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
3.7 [%]
p50122[0...n]
Field current for motor flux 10 % / I_field flux 10%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
7.3 [%]
p50123[0...n]
Field current for motor flux 15 % / I_field flux 15%
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
DDS, p0180
Func. diagram:
6900, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
0.0 [%]
100.0 [%]
11.0 [%]