SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
555
2 Parameters
2.2 List of parameters
Note:
The parameter can only be changed for the Control Module.
If value = 1:
The input signal is available via binector output r53140.4 for further interconnection.
If value = 2:
The input signal is available via binector output r53140.3 for further interconnection.
Description:
Sets the signal source for the "Fan On" relay output (terminal 120/121) on the power interface.
Note:
The parameter can only be changed for the Control Module.
Description:
Sets the delay times for device fan monitoring on the Control Module.
Index:
[0] = ON delay monitoring
[1] = ON delay fault
[2] = ON delay alarm
Dependency:
Refer to: A60266, F60267
Note:
The parameter can only be changed for the Control Module.
Description:
Sets the rated direct current of an external field device (if there is one).
Dependency:
Refer to: p50082
Note:
This parameter is only effective if p50082 >= 21.
Description:
Setting for activating/de-activating the monitoring for the external field.
Value:
0:
Deactivated
1:
Activated
p51834
BI: Signal source for device fan relay output / Fan relay sig s
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
6965, 8049
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p51835[0...2]
Delay times for device fan monitoring / Fan mon t_del
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
8049
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.0 [s]
60.0 [s]
[0] 15.0 [s]
[1] 5.0 [s]
[2] 2.0 [s]
p51838
Field device external rated direct current / I_rated ext
DC_CTRL
Can be changed:
T
Calculated:
-
Access level:
2
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6960, 6910
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [A]
600.00 [A]
0.00 [A]
p51839
External field monitoring / Ext field monit
DC_CTRL
Can be changed:
U, T
Calculated:
-
Access level:
2
Data type:
Integer16
Dyn. index:
-
Func. diagram:
8044
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0 1
0