SINAMICS DCM
List Manual (LH8), 02/2015, 6RX1800-0ED76
271
2 Parameters
2.2 List of parameters
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 4.
Dependency:
Refer to: r4760
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 5.
Dependency:
Refer to: r4760
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 6.
Dependency:
Refer to: r4760
Description:
Displays the trace buffer (record buffer) for trace 1 and signal 7.
Dependency:
Refer to: r4760
Description:
Sets the physical address for the first signal to be traced.
The data type is defined using p4730.
Index:
[0] = Trace 0
[1] = Trace 1
r4774[0...16383] Trace 1 trace buffer signal 4 / Trace 1 tr sig 4
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4775[0...16383] Trace 1 trace buffer signal 5 / Trace 1 tr sig 5
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4776[0...16383] Trace 1 trace buffer signal 6 / Trace 1 tr sig 6
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
r4777[0...16383] Trace 1 trace buffer signal 7 / Trace 1 tr sig 7
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
- -
-
p4780[0...1]
Trace physical address signal 0 / Trace PhyAddr Sig0
CU_DC, CU_DC_R,
CU_DC_R_S,
CU_DC_S
Can be changed:
U, T
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
-
P-Group:
Trace and function generator
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
0
Min Max
Factory
setting
0000 bin
1111 1111 1111 1111 1111 1111
1111 1111 bin
0000 bin
Summary of Contents for SINAMICS DCM
Page 1: ...s SINAMICS SINAMICS DCM List Manual 02 2015 Edition Answers for industry ...
Page 2: ......
Page 1192: ...A Appendix A 2 List of abbreviations SINAMICS DCM 1192 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1202: ...Index SINAMICS DCM 1202 List Manual LH8 02 2015 6RX1800 0ED76 ...
Page 1203: ......