2 Parameters
2.2 List of parameters
SINAMICS DCM
252
List Manual (LH8), 02/2015, 6RX1800-0ED76
Description:
Display and binector output to reset XIST1_ERW.
Dependency:
Refer to: p4652, r4653, p4655
Note:
The reset of XIST1_ERW is initiated via binector input p4655.
Binector output r4654 is reset with a 0 signal from binector input p4655.
Description:
Sets the signal source to reset XIST1_ERW (CO: r4653).
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = -
Dependency:
Refer to: p4652, r4653, r4654
Note:
The reset of XIST1_ERW depends on the selected mode (p4652).
Description:
Sets the filter bandwidth for Sensor Module SMx10 (resolver) and SMx20 (sin/cos).
The value set on the Sensor Module is displayed in r4661.
The Sensor Module hardware only supports the following values:
- 0: The Sensor Module's default is used.
- 50 kHz
- 170 kHz
- 500 kHz
- Unlimited: Only the bandwidth of the operational amplifier is effective.
Index:
[0] = Encoder 1
[1] = Encoder 2
[2] = Reserved
Dependency:
Refer to: r4661
Note:
A value of zero is displayed if an encoder is not present.
r4654.0...8
CO/BO: XIST1_ERW status / XIST1_ERW stat
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
-
Calculated:
-
Access level:
3
Data type:
Unsigned32
Dyn. index:
-
Func. diagram:
4750
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
-
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Encoder 1 XIST1_ERW reset
High
Low
-
08
Encoder 2 XIST1_ERW reset
High
Low
-
p4655[0...2]
BI: XIST1_ERW reset signal source / XIST1_ERW resS_src
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
T
Calculated:
-
Access level:
3
Data type:
Unsigned32 / Binary
Dyn. index:
-
Func. diagram:
4750
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
- -
0
p4660[0...2]
Sensor Module filter bandwidth / SM Filt_bandw
DC_CTRL,
DC_CTRL_R,
DC_CTRL_R_S,
DC_CTRL_S
Can be changed:
C2(4)
Calculated:
-
Access level:
3
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
-
P-Group:
Encoder
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
-
Expert list:
1
Min Max
Factory
setting
0.00 [kHz]
20000.00 [kHz]
0.00 [kHz]