2 Parameters
2.2 List of parameters
Description:
Displays the absolute value of the motor current setpoint.
Note:
This parameter is referred to the rated motor current.
The following applies: 100% corresponds to p50100[ii], whereby ii = active DDS
Description:
Displays the torque setpoint after limiting.
Note:
1 corresponds to 0.1% of the rated torque of the motor.
Description:
Displays the torque setpoint before limiting.
Note:
1 corresponds to 0.1% of the rated torque of the motor.
Description:
Display and connector output of the selected speed actual value on the speed controller.
Description:
Displays the speed setpoint before the ramp-function generator.
Dependency:
Refer to: r52193
r50020
Closed-loop armature current control motor current set abs value / Ia ctr I_set abs
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6855
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r50021
Torque limiting torque setpoint after limiting / Tqe set after lim
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6830
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r50022
Torque limiting torque setpoint before limiting / Tqe set bef lim
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6830
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r50025
Speed controller actual value selection / Act sel
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
6810
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
PERCENT
Expert list:
1
Min Max
Factory
setting
- [%]
- [%]
- [%]
r50028
Speed setpoint before the ramp-function generator display / n_set bef RFG disp
DC_CTRL
Can be changed:
-
Calculated:
-
Access level:
1
Data type:
FloatingPoint32
Dyn. index:
-
Func. diagram:
3135
P-Group:
-
Unit group:
-
Unit selection:
-
Not for motor type:
-
Scaling:
p2000
Expert list:
1
Min Max
Factory
setting
- [1 rpm]
- [1 rpm]
- [1 rpm]