AR-M550/M620/M700 SELF DIAG MESSAGE AND TROUBLESHOOTING 9 - 37
Main
code
Sub
code
Title
Memory check sum error (PCU)
U2
91
Phenomenon
Display
Lamp
Message
Details
Memory check sum error
(PCU)
When POF data/counter
data sum error is
detected.
Section
Engine
Operation
mode
Note
Case 1
Trouble
position/
Cause
EEPROM trouble
Remedy
Check that the EEPROM
is properly installed.
In the simulation to
prevent against delete of
the counter data/
adjustment values, write
down the counter/
adjustment values.
Note
Case 2
Trouble
position/
Cause
Control circuit runaway
due to noises
Remedy
Use SIM 16 to cancel the
U2 trouble.
Note
Case 3
Trouble
position/
Cause
PCU PWB EEPROM
access circuit trouble
Remedy
Replace the PCU PWB.
Note
Main
code
Sub
code
Title
SPF tray lift-up trouble
U5
30
Phenomenon
Display
Lamp
Message
Details
SPF tray lift-up trouble
Lift-up trouble is detected
5 times continuously.
Section
Scanner
Operation
mode
Note
Case 1
Trouble
position/
Cause
STUD/STLD trouble
STUD does not turn on
within the specified time.
STLD does not turn off
within the specified time.
Remedy
Check the harness and
the connector of the
STUD and STLD.
Lift-up trouble unit check
Note
Main
code
Sub
code
Title
SPF tray lift-down trouble
U5
31
Phenomenon
Display
Lamp
Message
Details
SPF tray lift-down trouble
STLD does not turn off
within the specified time.
Section
Scanner
Operation
mode
Note
Case 1
Trouble
position/
Cause
STUD/STLD trouble
STUD does not turn on
within the specified time.
STLD does not turn off
within the specified time.
Remedy
Check the harness and
the connector of the
STUD and STLD.
Lift-up trouble unit check
Note
Main
code
Sub
code
Title
LCC lift motor trouble
U6
09
Phenomenon
Display
Lamp
Message
Details
LCC lift motor trouble
• The upper limit sensor
does not turn on within
24 sec after the lift
motor is on.
• No rotation sensor
signal is detected for
0.2 sec or longer while
the lift motor is on.
• The upper limit switch
is on while the lift motor
is on.
When the trouble occurs
3 time continuously that
the upper limit sensor
does not turn on.
Section
LCC
Operation
mode
Note
Case 1
Trouble
position/
Cause
Sensor trouble
LCC control PWB trouble
Gear breakage
Lift motor trouble
Remedy
Use SIM to check the
sensor detection.
Use SIM to check the lift
motor operation.
Use SIM 15 to cancel the
trouble.
Note
Summary of Contents for AR-M550N
Page 456: ...Memo ...
Page 457: ...Memo ...