AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 156
7) Remove the toner bottle. (See “a. Toner bottle unit” in “[Toner
hopper and toner bottle section]”)
8) Remove the toner hopper unit. (See “b. Toner hopper unit” in
“[Toner hopper and toner bottle section]”)
9) Remove the developing unit. (See “a. Developing unit” in the
10) Remove the process unit. (See “a. Process unit” in the “[OPC drum
11) Raise the process DV cover diagonally, and remove the front right
cover.
12) Remove the front cabinet upper.
13) Remove the paper exit tray cabinet unit.
14) Remove the paper exit port cabinet, and remove the paper exit tray
cabinet C.
15) Disconnect the connector and remove the harness clamp. Remove
the main duct unit.
16) Remove the fan unit.
17) Disconnect the connector and remove the process exhaust fan
motor 1 (A), 2 (A), and 3 (C).
NOTE: When assembling, fit the mark with the fan rotating direction
(label on the back surface).