AR-M550/M620/M700 SIMULATION 8 - 96
Operation/Procedure
1) Select YES/NO of Modem program reload.
2) Press [START] key.
When reload is completed normally, "OK" is displayed. In case of an
error, "CHECK SUM" is displayed.
The result of Modem reload is displayed.
Operation/Procedure
1) Enter the number corresponding to the check mode with 10-key.
2) Press [START] key.
When check is completed normally, "OK" is displayed. Incase of an
error, "NG" is displayed.
When check is "repeat," the operation is continued until the result is
NG or [CUSTOM SETTINGS] key is pressed.
Operation/Procedure
1) Enter the number corresponding to the destination.
2) Press [START] key.
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
The item list menu can be switched by pressing [P] key.
2) Press [START] key.
3) Enter the set value.
4) Press [START] key.
This simulation can be executed when soft SW 24-4 and 24-5 are set
to 1. Display/Not display is switched by soft SW 24-4 and 24-5.
The digit limitation and characters allowed to be inputted depend on
the input item.
66-35
Purpose
Setting
Function
(Purpose)
Modem program reloading (Only when FAX is
installed)
Not used in the market. (For development)
Section
FAX
Item
Data
1
YES
Modem block reload is cleared.
2
NO
Not reloaded.
COMPLETE
Reload completed
81
Check sum error
82
Write error
83
Delete error
84
Verify error
NG
Due to loader NG
Press [START] key.
After completion of reloading
66-36
Purpose
Operation test/Check
Function
(Purpose)
Used to check interface between MFPC controller and
MDMC. (Check of the data line or the command line)
Section
FAX
Item
Operation
1
MFPC
←
MDMC
Date line once only
2
MFPC
→
MDMC
Date line once only
3
MFPC
←
MDMC
Data line repeat
4
MFPC
→
MDMC
Data line repeat
5
MFPC
←
MDMC
Command line once only
6
MFPC
→
MDMC
Command line once only
7
MFPC
←
MDMC
Command line repeat
8
MFPC
→
MDMC
Command line repeat
SIMULATION 66-35
MODEM PROGRAM RELOAD.
ARE YOU SURE?
1. YES
2. NO
1
SIMULATION 66-35
MODEM PROGRAM RELOAD.
EXECITOMG···
LOADER··· xxxxx
MODEM···· xxxxx
SIMULATION 66-35
MODEM PROGRAM RELOAD.
LOADER···OK
MODEM····COMPLETE
66-39
Purpose
Setting
Function
(Purpose)
Used to set the destination specifications.
Section
FAX
Item
Specifications Operation
66-60
Purpose
Setting
Function
(Purpose)
Used to set the ACR data.
Section
FAX
Item
Operation
SIMULATION 66-36
MFPC-MDMC I/F CHECK. INPUT 1-8, AND PRESS START.
1. MFPC<-MDMC(DATA once)
2. MFPC->MDMC(DATA once)
3. MFPC<-MDMC(DATA repeat)
4. MFPC->MDMC(DATA repeat)
5. MFPC<-MDMC(CMD once)
6. MFPC->MDMC(CMD once)
7. MDPC<-MDMC(CMD repeat)
8. MFPC->MDMC(CMD repeat)
1
SIMULATION 66-36
MFPC-MDMC I/F CHECK. INPUT 1-8, AND PRESS START.
EXECUTING...(OK or NG)
SIMULATION 66-36
MFPC-MDMC I/F CHECK. INPUT 1-8, AND PRESS START.
EXECUTING...
Press [START] key.
When check is "once" or
"repeat" and the result is "NG":
When check is "repeat" and
[CUSTOM SETTINGS] key ON:
Press [START] key.
SIMULATION 66-39
FAX DESTINATION SETUP.
SELECT 1-6, AND PRESS START
0. NO DESTINATION
1. JAPAN
2. U.S.A./CANADA
3. EUROPE
4. AUSTRALIA
5. CHINA
6. ASIA
1