AR-M550/M620/M700 SELF DIAG MESSAGE AND TROUBLESHOOTING 9 - 15
Main
code
Sub
code
Title
Finisher communication trouble
F1
00
Phenomenon
Display
Lamp
Message
Details
Finisher communication
trouble
An error in the
communication line test
after turning on the power
or canceling the
simulation
Communication error with
the finisher
Follows the
communication protocol
specifications.
Communication error,
timing abnormality of the
communication data and
the communication signal
line
Section
Engine
Operation
mode
Note
Case 1
Trouble
position/
Cause
Improper connection or
disconnection of the
connector or harness
between the machine and
the finisher
Remedy
Check the connector and
the harness in the
communication line.
Note
Case 2
Trouble
position/
Cause
Finisher control PWB
trouble
Control PWB (PCU)
trouble
Remedy
Replace the finisher
control PWB or the PCU
PWB.
Note
Case 3
Trouble
position/
Cause
Malfunction caused by
noises
Remedy
Canceled by turning ON/
OFF the power.
Note
Main
code
Sub
code
Title
Finisher transport motor
abnormality
F1
02
Phenomenon
Display
Lamp
Message
Details
Finisher transport motor
abnormality
When opening the shutter
unit, the opening process
is not completed in 1sec.
When closing the shutter
unit, the closing process
is not completed in 1sec.
When the tray lift unit is
operating in the
dangerous area, “Not
closed state” of the
shutter close sensor is
detected.
Section
Finisher
Operation
mode
Note
Case 1
Trouble
position/
Cause
Motor lock
Motor RPM abnormality
Overcurrent to the motor
Finisher control PWB
trouble
Remedy
Use SIM 3-3 to check the
transport motor operation.
Note
Main
code
Sub
code
Title
Finisher oscillation motor trouble
F1
03
Phenomenon
Display
Lamp
Message
Details
Finisher oscillation motor
trouble
When opening the
oscillation unit, the
opening process is not
completed in 1sec.
When closing the
oscillation unit, the
closing operation is not
completed in 3sec.
When the tray lift unit is
operating in the
dangerous area, “Not
closed state” of the
oscillation unit close
sensor is detected.
When controlling the
oscillation unit speed, the
encoder input cannot be
detected within a
specified time.
Section
Finisher
Operation
mode
Note
Case 1
Trouble
position/
Cause
Motor lock
Motor RPM abnormality
Overcurrent to the motor
Finisher control PWB
trouble
Remedy
Use SIM 3-3 to check the
motor operation.
Note
Summary of Contents for AR-M550N
Page 456: ...Memo ...