
: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 75
Operation/Procedure
1) Set the SPF paper feed guide to the max. position.
2) Select "MAX. POSITION" with 10-key.
3) Press [START] key.
The max. width detection level is recognized.
4) Press [CSUTOM SETTING] key.
5) Set the SPF paper feed guide to A4R size position.
6) Select POSITION 1 with 10-key.
7) Press [START] key.
The A4R width detection level is recognized.
8) Press [CSUTOM SETTING] key.
10) Select POSITION 2 with 10-key.
11) Press [START] key.
12) Press [CSUTOM SETTING] key.
13) Set the SPF paper feed guide to the min. position.
14) Select "MIN. POSITION" with 10-key.
15) Press [START] key.
The min. width detection level is recognized.
If the above procedures are not completed normally, ERROR is dis-
played. When completed normally, COMPLETE is displayed.
Operation/Procedure
1) Enter the number corresponding to the set item with 10-key.
2) Press [START] key.
3) Enter the set value with 10key.
4) Press [START] key.
Select 0, and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
53
53-6
Purpose
Adjustment
Function
(Purpose)
Used to adjust the DSPF width detection level.
Section
Item
Operation
9) Set the SPF paper feed guide to A5R size position.
The A5R width detection level is recognized.
50
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 0-14, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.TRAY1
46
3.TRAY2
45
4.TRAY3
46
5.TRAY4
46
6.BPT
45
7.LCC
45
8.ADU
43
9.SPF(TOP)
50
10.SPF(HIGH)
50
11.SPF(LOW)
50
12.SPF FEED(TOP)
50
13.SPF FEED(HIGH)
50
14.SPF FEED(LOW)
50
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. NOW PRINTING.
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
1.TRAY1
Select 1,
and press
[START] key.
Select other than 0 - 1, and
press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
1
SIMULATION 51-2
RESIST TIMING ADJUSTMENT. SELECT 1-15, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
1
1
Select 4, and press [START] key.
Press [CUSTOM SETTINGS]
key.
53-7
Purpose
Adjustment/Setup/Operation data output/Check
(Display/Print)
Function
(Purpose)
Used to enter the SPF width detection adjustment
value.
Section
DSPF
Item
Operation
Item
Set range
Default
1
MAX. POSITION
Max. width
0 - 1023
66
2
POSITION 1
Adjustment position 1
456
3
POSITION 2
Adjustment position 2
713
4
MIN. POSITION
Min. width
791
Press [START] key.
Press [CUSTOM SETTINGS] key.
1
Select 2, and press [START] key.
Select 3, and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
Press [CUSTOM SETTINGS] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT. SELECT 1-4, AND PRESS START.
1.MAX.POSITION
2.POSITION 1
3.POSITION 2
4.MIN.POSITION
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MAX.POSITION ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 1 ... COMPLETE (or “ERROR”)
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
POSITION 2 ... COMPLETE (or “ERROR”)
Select 1, and
press [START] key.
SIMULATION 53-6
SPF TRAY ADJUSTMENT.
MIN.POSITION ... COMPLETE (or “ERROR”)
1
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). SELECT 1-4, AND PRESS
START.
1.MAX.POSITION:
66
2.POSITION 1 :
456
3.POSITION 2 :
713
4.MIN.POSITION:
791
66
SIMULATION 53-7
SPF TRAY ADJUSTMENT(MANUAL). INPUT VALUE 0-1023, AND
PRESS START.
1.MAX.POSITION
Summary of Contents for AR-M550N
Page 456: ...Memo ...
Page 457: ...Memo ...