AR-M550/M620/M700 SIMULATION 8 - 65
The greater the value is, the greater the correction is. One step corre-
sponds to 0.1% adjustment.
(Copy condition setting in this simulation)
∗
To select paper (paper feed tray), perform the following procedures.
1) Enter 0 with 10-key.
2) Press [START] key. (The mode is changed to the paper feed tray
selection mode.)
3) Enter the number corresponding to the paper feed tray of the
selected paper with 10-key. (Select one of 1 - 6.)
4) Press [START] key. (The paper feed tray is selected.)
When the total of the above set value (1 - 6) and 10 is entered, the
mode is changed to the duplex mode.
∗
The copy magnification ratio can be set with the following
1) Enter 2 with 10-key.
2) Press [START] key.
3) Enter the copy magnification ratio with 10-key.
4) Press [START] key.
NOTE: When [P] key is pressed after entering the adjustment value,
the adjustment value is set. When [START] key is pressed
instead, the adjustment value is set and copying is performed.
Operation/Procedure
When the sub scanning direction image magnification ratio adjustment
with SIM 48-1 cannot provide a satisfactory result if a different magnifi-
cation ration is set and a copy is made, perform this simulation.
When there is an error in the copy magnification ratio in reduction
copy, change the adjustment value of the high speed mode. When
there is an error in the copy magnification ratio in enlargement copy,
change the adjustment value of the low speed mode.
1) Select the number corresponding to the adjustment mode with 10-
key.
2) Press [START] key.
3) Enter the copy adjustment value with 10-key.
The scanner/SPF motor rotation sped adjustment value is entered.
4) Press [START] key.
Operation/Procedure
(Lead edge image loss/void area adjustment)
1) Set the lead edge image loss adjustment value (LEAD EDGE) and
the paper lead edge void adjustment value (DENA) as follows.
(Standard set value) Lead edge image loss: 1.5mm (LEDA: 15)
Paper lead edge void: 3.5mm (DENA: 35)
∗
Set LEAD to 15. (Enter 15 as the adjustment value of LEAD, and
press [P] key.) (0.1mm/step)
1
TRAY1
TRAY1
2
TRAY2
TRAY2
3
TRAY3
TRAY3
4
TRAY4
TRAY4
5
BPT
Manual feed
6
LCC
Side LCC
Set range
25 - 400%
Select 2, and
press [START] key.
Press [START] key, or
press [CUSTOM SETTINGS] key.
50
1
2
Select other than 0 - 2,
and press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key,
or terminate copying.
Press [START] key, or
press [CUSTOM SETTINGS] key.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 0-7, AND PRESS START.
0.TRAY SELECT
1
1.PRINT START
2.MAGNIFICATION
100
3.CCD(MAIN)
50
4.CCD(SUB)
50
5.SPF(SUB)
50
6.CIS(MAIN)
50
7.SPF(MAIN)
50
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. INPUT VALUE 0-99, AND PRESS
START.
4.CCD(SUB)
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. NOW COPYING.
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT. SELECT 1-16, AND PRESS START.
(FEED TRAY)
1.TRAY1 2.TRAY2 3.TRAY3 4.TRAY4
5.BPT 6.LCC
(ABOVE+10: DUPLEX MODE)
Select 1, and
press [START] key.
Select 0, and press [START] key.
1
1
100
SIMULATION 48-1
MAGNIFICATION ADJUSTMENT.
(MAGNIFICATION)
INPUT 25-400(%)
48-5
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy magnification ratio in the sub
scanning direction.
Section
Optical (Image scanning)
Item
Picture quality
Item
Content
Set
range
Default
0
MIR (220)
Mirror motor (220mm/sec)
0 - 99
50
1
MIR (110)
Mirror motor (110mm/sec)
2
SPF (360)
SPF motor (360mm/sec)
3
SPF (220)
SPF motor (220mm/sec)
4
SPF (110)
SPF motor (110mm/sec)
Select other than 0 - 5, and
press [START] key.
Press [START] key, or press
[CUSTOM SETTINGS] key.
50
50-1
Purpose
Adjustment
Function
(Purpose)
Used to adjust the copy image position and the void
area (image loss) adjustment on print paper in the
copy mode. (The similar adjustment can be performed
with SIM 50-5 and 50-2 (Simplified method).)
(Document table mode)
Section
Item
Picture quality
Image position
0
SIMULATION 48-5
MOTOR SPEED ADJUSTMENT. SELECT 0-4, AND PRESS START.
0.MIR(220)
50
1.MIR(110)
50
2.SPF(360)
50
3.SPF(220)
50
4.SPF(110)
50
50
SIMULATION 48-5
SCAN MOTOR SPEED ADJUSTMENT. INPUT VALUE 0-99, AND
PRESS START.
0.MIR(220)