: Feb. 9 2004
1
AR-M550/M620/M700 SIMULATION 8 - 28
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the output corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The main charger grid output voltage adjustment and output check
can be made in each print mode.)
Operation/Procedure
1) Enter the number corresponding to the adjustment item with 10-
key.
2) Press [START] key.
3) Enter the adjustment value with 10-key.
4) Press [START] key.
(The set value is stored, and the voltage corresponding to the set
value is outputted for 30sec.)
Press [CUSTOM SETTINGS] key to stop the operation.
(The transfer output voltage adjustment and output check can be made
in each print mode.)
Item
Set range
Default
1
AUTO
Auto mode
0 - 750
495
2
CHARACTER
Text mode
3
MIX
Text/Photo mode
4
PHOTO
Photo mode
5
PRINTER
Printer mode
6
FAX
FAX mode
7
PLUS
Reverse developing
bias voltage
0 - 250
150
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-2
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the main
charger grid voltage in each printer mode and the
control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
Set range
Default
1
AUTO
Auto mode
200 - 1000
580
2
CHARACTER
Text mode
3
MIX
Text/Photo mode
4
PHOTO
Photo mode
5
PRINTER
Printer mode
6
FAX
FAX mode
SIMULATION 8-1
1
DV BIAS SETTING. SELECT 1-7, AND PRESS START.
1.AUTO
495
2.CHARACTER
495
3.MIX
495
4.PHOTO
495
5.PRINTER
495
6.FAX
495
7.PLUS
150
SIMULATION 8-1
DV BIAS SETTING. INPUT VALUE, AND PRESS START.
1:AUTO (0-750)
495
SIMULATION 8-1
DV BIAS SETTING. EXECUTING···.
1:AUTO
495
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
8-6
Purpose
Adjustment/Operation test/Check
Function
(Purpose)
Used to check and adjust the operation of the transfer
voltage and the control circuit.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)/Transfer
Item
Set
range
Default
AR-M550N/U,
AR-620N/U
AR-M700N/U
1
FRONT
Long side print
mode
0 - 800
300
400
2
BACK
Back side print
mode
300
400
SIMULATION 8-2
1
MAIN GRID SETTING. SELECT 1-6, AND PRESS START.
1.AUTO
580
2.CHARACTER
580
3.MIX
580
4.PHOTO
580
5.PRINTER
580
6.FAX
580
SIMULATION 8-2
MAIN GRID SETTING. INPUT VALUE, AND PRESS START.
1.AUTO (200-1000)
580
SIMULATION 8-2
MAIN GRID SETTING. EXECUTING···.
1.AUTO
580
1
1
1
Press [START] key.
Press [CUSTOM SETTINGS] key.
Press [START] key.
Press [CUSTOM SETTINGS] key.
Or after 30sec output.
SIMULATION 8-6
1
THV+ SETTING. SELECT 1-2, AND PRESS START.
1.FRONT
300
2.BACK
300
SIMULATION 8-6
THV+ SETTING. INPUT VALUE, AND PRESS START.
1.FRONT(0-800)
300
SIMULATION 8-6
THV+ SETTING. EXECUTING···.
1.FRONT
300
Summary of Contents for AR-M550N