: Feb. 6 2004
1
AR-M550/M620/M700 DETAILS OF EACH SECTION 6 - 79
a-2. Separation pawl
1) Remove the OPC drum. (See “a-1. OPC drum” in this section)
2) Remove the plastic E-ring.
3) Remove the separation pawl.
a-3. Cleaning blade
1) Remove the OPC drum. (See “a-1. OPC drum” in this section)
2) Remove the cover.
3) Remove the cleaning blade.
a-4. Toner receiving seal
1) Remove the OPC drum. (See “a-1. OPC drum” in this section)
2) Remove the toner receiving seal.
a-6. Brush roller
1) Remove the OPC drum. (See “a-1. OPC drum” in this section)
2) Remove the toner receiving seal.
3) Remove the blue screw to remove the lever.
a-5. Side seal F/R
a-6. Side seal R base sheet
1) Remove the OPC drum unit. (See “a-1. OPC drum” in this section)
2) Remove the side seal R base sheet.
3) Attach the side seal R base sheet to the specified position. Attach
the side seals F/R to the specified positions.
NOTE: Clean and remove toner and dust from the attachment section
with alcohol.
NOTE: When replacing the side seals F/R, apply friction-reducing
powder (UKOG-0309FCZZ) to all over the side seals F/R in
order to reduce friction and membrane decrease of the OPC
layer on both sides of the OPC drum. (Use PARTEL (UKOG-
0311FCZZ).)
1