AR-M550/M620/M700 SIMULATION 8 - 41
Operation/Procedure
1) Press [START] key.
The developing motor and the OPC drum motor rotate, and the
toner concentration detection level and the humidity sensor detec-
tion level are displayed.
Operation/Procedure
1) Press [START] key.
The developing motor rotates for 3 min and the toner concentration
sensor makes sampling of toner concentration to display the
detection level.
After the developing motor stops, the average value of toner con-
centration sampling is set as the reference toner concentration
level.
NOTE: When the above operation is interrupted on the way, the refer-
ence toner concentration level is not set. Also when error code
of EE-EL or EE-EU is displayed, the reference toner concentra-
tion level is not set normally.
(Default: 114)
Operation/Procedure
1) Select the number corresponding to the paper feed unit for setting
the paper size with 10-key.
2) Press [START] key.
3) Select the number corresponding to the paper size.
4) Press [START] key.
Operation/Procedure
1) Select the number corresponding to the auditor mode with 10-key.
2) Press [START] key.
(Default: 1)
Press [START] key.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after 3 min.
25-2
Purpose
Setting
Function
(Purpose)
Used to make the initial setting of toner concentration
when replacing developer.
Section
Image process (Photoconductor/Developing/Transfer/
Cleaning)
Item
2) The humidity near the developing tank at the developing adjust-
ment is registered.
Press [START] key.
Press [CUSTOM SETTINGS] key, and the
operation is stopped immediately or after 3 min.
SIMULATION 25-1
TONER SENSOR OUTPUT MONITOR. PRESS START.
HUMIDITY AREA :
70.0
-
72.5
DEVE REFERENCE :
128
SIMULATION 25-1
DV MONITOR. EXECUTING···.
HUMIDITY AREA :
70.0
-
72.5
DEVE REFERENCE :
128
1
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. PRESS START.
HUMIDITY AREA :
70.0
-
72.5
DEVE REFERENCE :
114
1
SIMULATION 25-2
AUTOMATIC DV ADJUSTMENT. EXECUTING···.
HUMIDITY AREA :
70.0
-
72.5
DEVE REFERENCE :
114
26
26-2
Purpose
Setting
Function
(Purpose)
Used to set the paper size of the large capacity tray
(LCC) and the paper feed tray 2. (When the paper size
is changed, this simulation must be executed to
change the paper size in software.)
Section
Paper feed
Item
Setting
1
TRAY 2
TRAY 2 size (0 = 8.5 x 11, 1 = A4, 2 = B5)
2
LCC
Side LCC size (0 = 8.5 x 11, 1 = A4, 2 = B5)
Press [START] key.
Press [CUSTOM SETTINGS] key.
26-3
Purpose
Setting
Function
(Purpose)
Used to set the specifications of the auditor. Setting
must be made according to the auditor use conditions.
Section
Auditor
Item
Specifications
1
P10
Built-in auditor mode
2
VENDOR
Coin vendor mode
3
OTHERS
Other
SIMULATION 26-2
1
SIZE SETUP. SELECT NUMBER, AND PRESS START.
1. TRAY2
1
2. LCC
1
SIMULATION 26-2
LCC SIZE SETUP. SELECT 0-2, AND PRESS START.
0. 8.5x11
1. A4
2. B5
1
SIMULATION 26-3
AUDITOR SETUP. SELECT 1-3, AND PRESS START.
1. P10
2. VENDOR
3. OTHERS
1
Summary of Contents for AR-M550N
Page 456: ...Memo ...
Page 457: ...Memo ...