153
Analysis of this segment data:
01H address of the driver
13H read function code
000CH start address, equivalent to F0.12 0f control panel
0004H register amount
45CBH 16 bits of CRC check code
6) 13H read single parameter (including attribute, min.value, max.value)
Inquiry information frame format (Send frame):
Address
01H
Function
13H
Starting data address
00H
0CH
Number of Data(Byte)
00H
04H
CRC CHK High
45H
CRC CHK Low
CBH
Inquiry information frame format(Return frame):
Address
01H
Function
13H
Starting data address
00H
12H
Data1(2Byte)
13H
88H
Data2(2Byte)
03H
22H
Data3(2Byte)
00H
00H
Data4(2Byte)
13H
88H
CRC CHK High
28H
CRC CHK Low
31H
Communication Protocol