041
F5 Group - VF Control Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F5.00
V/F curve set
0: linear curve
1: decreasing torque curve 1( 1.3
power)
2: decreasing torque curve 2(1.5
power)
3: decreasing torque curve 3(1.7
power)
4: square curve
5: user set V/F curve
(determined by F5.01 ~ F5.06)
1
0
×
F5.01
V/F frequency F1 0.00 ~ F2 (frequency value) 0.01Hz
12.50
×
F5.02
V/F voltage V1
0.0 ~ V2 (voltage value)
0.1%
25.0%
×
F5.03
V/F frequency F2 F1 ~ F3 (frequency value)
0.01Hz
25.00
×
F5.04
V/F voltage V2
V1 -V3 (voltage value)
0.1%
50.0%
×
F5.05
V/F frequency F3 Freq. Value F2 ~ 【F2.02】rated
freq. of motor
0.01Hz
37.50
×
F5.06
V/F voltage V3
Voltage value V2 ~ 100.0%*
【F2.04】rated voltage of motor
0.1%
75.0%
×
F5.07
Torque boost
setting
0.0 ~ 30.0%*rated voltage of
motor 【F2.04】
0.1% Depending
on model
×
F5.08
Torque boost
cutoff point
0.00 ~ rated freq. of motor
0.01Hz
50.00
×
F5.09
V/F control
slip frequency
compensation
0.0 ~ 200.0% *rated slip
note: default as 100.0% in
advanced VF control mode
0.1%
0.0%
○
F5.10
V/F control slip
compensation
filtering
coefficients
1 ~ 10
1
3
○
F5.11
V/F control
torque
compensation
filtering
coefficients
0 ~ 10
1
0
○