051
4.1 Function Code
F7 Group - Digital Input and Output Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F7.07 reserved
—
—
0
◆
F7.08 Digital filtering
times
1 ~ 10 1: 2MS unit of scanning
time
1
5
○
F7.09
Terminal function
detection when
power on
0: terminal operation command
invalid when power on
1: terminal operation command
valid when power on
1
0
○
F7.10
Effective logic
setting of input
terminal (X1 ~ X8)
0 ~ FFH
0 is positive logic, i.e. terminal Xi
is enabled when it connects with
common terminal and disabled
if disconnected.
1 is negative logic, i.e. terminal
Xi is disabled when it connects
with common terminal and
enabled when disconnected.
1
00
×
F7.11 FWD/REV terminal
control mode
0: two-wire control mode 1
1: two-wire control mode 2
2: three-wire control mode 2
3: three-wire control mode 1
1
0
×
F7.12
UP/DOWN
terminal frequency
modifying rate
0.01 ~ 50.00Hz/s
0.01Hz/s
1.00
○
F7.13 reserved
—
—
0
◆
F7.14 Y1 output delay
time
0.0 ~ 100.0s
0.1s
0.0
×
F7.15 Y2 output delay
time
0.0 ~ 100.0s
0.1s
0.0
×
F7.16 R1 output delay
time
0.0 ~ 100.0s
0.1s
0.0
×
F7.17 R2 output delay
time (reserved)
0.0 ~ 100.0s
0.1s
0.0
×