038
4.1 Function Code
F4 Group - Speed Loop, Torque and Flux Control Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F4.04 Speed loop (ASR2)
proportional gain
0.000 ~ 6.000
0.001
1.500
○
F4.05 Speed loop (ASR2)
Integral time
0.000 ~ 32.000s
0.001s
0.500
○
F4.06 ASR2 filter time
constant
0.000 ~ 0.100s
0.001s
0.000
○
F4.07 Switch high point freq. 【F4.03】~【F0.16】upper
limit freq.
0.01Hz
10.00
○
F4.08
Vector control
of positive slip
compensation factor
(electromotion state)
50.0% ~ 200.0%*rated slip
frequency
0.1%
100.0%
○
F4.09
Vector control
of negative slip
compensation factor
(braking state)
50.0% ~ 200.0%*rated slip
frequency
0.1%
100.0%
○
F4.10 Speed and torque
control
0: speed
1: torque
2: valid conditionally
(terminal switch)
1
0
×
F4.11 Speed and torque
switching delay
0.01 ~ 1.00s
0.01s
0.05
×
F4.12 Torque command
0: keypad set
1: AI1
2: AI2
3: communication set
1
0
○