4.1 Function Code
F7 Group - Digital Input and Output Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default Modification
F7.21 Programmable
relay R2 output
26: dynamic braking action
27: DC braking action
28: flux braking action
29: torque limiting
30: over torque signal
31: auxiliary motor 1
32: auxiliary motor 2
33: accumulated operation time out
34 ~ 49: segment of MS or simple PLC
operation
50: running indication signal
51: temperature arrival indication
52: indicate when VFD stops or runs at
zero speed
53: reserved
54: reserved
55: communication setting
56: drive ready 2
57: The output indication signal is
output when AI1 input over limit.
58 ~ 99: reserved
1
0
×
F7.22
Logic setting of
output terminal
(Y1 ~ Y2)
0 ~ 3H
0: positive logic, i.e. terminal Yi is
enabled when it connects with
common terminal, and disabled if
disconnected.
1: negative logic, i.e. terminal Yi
is disabled when it connects with
common terminal, and enabled if
disconnected.
1
0
×
F7.23
Freq. arrival
detectionrange
(FAR)
0.0 ~ 100.0% *【F0.15】max. freq.
0.1%
10.0%
○
F7.24 FDT1 detection
method
0: speed set value
1: speed detected value
1
0
○