Warning:
For some serious fault, such as inverse module protect, over current, over voltage, etc., do not conduct fault
reset forcibly to make the inverter run again without fault elimination confirmed, or might cause damage to the
inverter.
3.7 Monitoring Parameter
Example 1: status parameter display switching
Under monitoring status, press key, the display will switch automatically to according
value of monitoring parameter according to FD group status monitoring parameter setting, and
meanwhile the corresponding unit indicator light will be on. For example, press to switch
to output frequency D-00, and the indicator light of unit "Hz" is on.
0.00
50.00
3.6 Function Code Editing Display
Under stop, run or fault alarm status, press key to enter editing status which is displayed as
two classes menu (input the password first if it is preset, see password unlock instruction). Press
key to enter items one class by one class. Under function parameter display status, press
to conduct storage operation, press key to return to the upper class menu without
storing modified parameter.
PRG
PRG
ENTER
ENTER
PRG
PRG
PRG
ENTER
0.00
F0.00
d-00
D-05
*****
Escape
▲
▼
Example 2: check monitoring parameter item d-05 (output current)
Method 1:
Press key to enter programming status, LED displays function code F0.00, press again
key, LED displays function code d-00, flicker bit stays in ones place, adjust key or
key until the monitoring code turns d-05.
Press key, the according value of d-05 displays and the indicator light of unit "A" is on.
Press key, escape from monitoring status.
PRG
ENTER
PRG
PRG
▲
▼
①
②
③