136
FC.20
Oscillation suppressing factor
0.00 ~ 300.00
0
This parameter is used to adjust the flux
braking ability during decelerating. The larger
of the value, the stronger of the flux braking
ability, and the shorter of the decelerating
time. Normally there is no need to set it. This
function is disabled if the parameter is set at 0.
When overvoltage limit level is low, this
function can help reducing decelerating
time. Otherwise there is no need to open this
function.
FC.21
Flux braking
0 ~ 100
0
FC.22
Energy saving control factor
0 ~ 100
0
The larger of the setting value, the better
of the energy saving effect, but may cause
unstable operation. This function is only valid
for V/F control mode, and is disabled when set
at 0.
0: disabled
1: MS prior to F0.07 setting.
FC.23
MS priority
0 ~ 1
0
0: disabled
1: the jog has the highest priority during the
driver operation.
FC.24
Jog priority
0 ~ 1
0
LED one's place: A02 and D0 output selection
0: A02 enabled
1: D0 enabled
LED ten's place: reserved
LED hundred's place: reserved
LED thousand's place: reserved
FC.25
Special function
0000 ~ 0001
10
FC.26
Upper frequency of oscillation
suppression
0.00 ~ 300.00Hz
50.00
FC.27
Oscillation suppression coefficient
1 ~ 500
50.00
FC.28
Oscillation suppression voltage
0.0 ~ 25.0%*motor rated
voltage
5.0
4.2 Detailed Function Description
when the driver works with a heavy load for
a long time or high frequency (over 50Hz)
operation torque is insufficient.
LED hundred's place: dead-time compensation
0: disabled
1: enabled
If it is enabled, dead time compensation
of all band will be conducted in all
control modes. This function is mainly
for manufacturer debugging, and not
recommended to set by customers.
LED thousand's place: harmonic components
optimizing (reserved)
0: disabled
1: enabled