046
4.1 Function Code
F6 Group - Analog Quantity and Pulse Input and Output Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default Modification
F6.21
AO1 multi-function
analog output
terminal
0: output frequency ( before
slip compensation)
1: output frequency (after slip
compensation)
2: set frequency
3: motor speed (estimated
value)
4: output current
5: output voltage
6: but voltage
7: PID specified value
8: PID feedback value
9: AI1
10: AI2
11: input pulse freq.
12: torque current
13: flux current
1
0
○
F6.22
A02 multi-function
analog output
terminal
1
4
○
F6.23
DO multi-function
impulse output
terminal
1
11
○
F6.24
Physical quantity
correspond to AO1
output lower limit
-200.0% ~ 200.0%
0.1%
0.0%
○
F6.25 AO1 output lower limit 0.00 ~ 10.00V
0.01V
0.00
○
F6.26
Physical quantity
correspond to AO1
ouput upper limit
-200.0% ~ 200.0%
0.1%
100.0%
○
F6.27 AO1 output upper limit 0.00 ~ 10.00V
0.01V
10.00
○
F6.28
Physical quantity
correspond to AO2
output lower limit
-200.0% ~ 200.0%
0.1%
0.0%
○
F6.29 AO2 output lower limit 0.00 ~ 10.00V
0.01V
0.00
○
F6.30
Physical quantity
correspond to AO2
output upper limit
-200.0% ~ 200.0%
0.1%
100.0%
○
F6.31 AO2 output upper limit 0.00 ~ 10.00V
0.01V
10.00
○
Summary of Contents for SKI600
Page 3: ......
Page 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Page 179: ......