068
4.1 Function Code
FC Group - Advanced Function and Performance Parameters
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
FC.19 AVR function
LED one's place: AVR
function
0: disabled
1: always enabled
2: only disabled when
decelerating
LED ten's place:
overmodulation
0: disabled
1: enabled
LED hundred's place: dead-
time compensation
0: disabled
1: enabled
LED thousand's place:
harmonic components
optimizing
(reserved)
0: disabled
1: enabled
1
1102
×
FC.20 Oscillation suppressing
initial freq.
0.00 ~ 300.00Hz
0.01
Depending
on model
○
FC.21 Flux braking
0 ~ 100 0: disabled
1
0
○
FC.22 Energy saving control
factor
0 ~ 100 0: disabled
1
0
○
FC.23 MS priority
0: disabled
1: MS prior to F0.07 setting
1
0
×