114
Fig. F7-9 Counter Reset and
Detection Setting
0: start during power on
1: start in running status, stop in stop status
These above is based on premise of
counting impulse.
F7.31
Counting start condition
0 ~ 1
1
0: stop timing, stop output
1: stop timing, continue output
2: cycle timing, stop output
3: cycle timing, continue output
This action is executed when the counting
value arrives at preset value of F7.36.
F7.34
Time out processing
0 ~ 3
3
0: start during power on
1: start in running status, stop in stop status.
F7.35
Timing start condition
0 ~ 1
1
F7.36
Timing setting
0 ~ 65535s
0
F7.37
Y1 turn off delay time
0.0 ~ 100.0s
0.0
F7.38
Y2 turn off delay time
0.0 ~ 100.0s
0.0
F7.39
R1 turn off delay time
0.0 ~ 100.0s
0.0
F7.40
R2 turn off delay time
0.0 ~ 100.0s
0.0
This function code defines counting reset
value and detection value of counter. When
the counting value arrives at the preset value
of F7.32, the corresponding multi-function
output terminal will send out valid signal and
the counter will be cleared to zero.
When the counting value reaches the preset
value of F7.33, the corresponding output
terminal (output signal of counter detection)
sends out valid signal. If the counting
continues and exceeds the preset value of
F7.32, this output signal will be revoked when
the counter is cleared.
As showed in the following figure: the
programmable relay output is set as reset
signal output, open collector output Y1 is set
as counter detection output, F7.32 is set as 8,
F7.33 is set as 5. When the detection value is
5, Y1 output valid signal and maintain it; when
detection value arriving at reset value 8, the
relay output valid signal of one cycle impulse
and the counter is cleared, meanwhile, Y1 and
relay will revoke output signal.
F7.32
Counter reset value
【F7.33】~ 65535
0
F7.33
Counter detection value
0 ~【F7.32】
0
3FMBZ
%*
:
4.2 Detailed Function Description
Summary of Contents for SKI600
Page 3: ......
Page 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Page 179: ......
Page 180: ......