158
5.7 Parameter Attribute:
bit
meaning
Bit15
reserved
Bit14
menu
Bit13
system
Bit12
reset to factory defaults
Bit11
EEPROM
Bit10 ~ Bit9
" ○ ": 01
" × ": 10
" ◆ ": 11
" ◇ ": 00
Bit8
sign
Bit7 ~ Bit3
1: 00000
V: 00001
A: 00010
rpm: 00011
HZ: 00100
%: 00110
S: 01000
KHZ: 01100
KW: 01010
om: 01110
ms: 01001
MA: 01011
KM: 01101
CM: 01111
us: 10001
HZ/S: 10000
mh: 10010
C: 10011
m/s: 10100
H: 10101
KWH: 10110
Bit2 ~ Bit0
Decimal point
5.8 Error Code from Slave Response of Abnormal Information:
Error code
description
01H
Invalid function code
02H
Invalid address
03H
Invalid data
04H
Invalid register length
05H
CRC validation error
06H
Parameters can't be changed during running
07H
The changes of parameters are invalid
08H
Control command of host is invalid
09H
Parameter protected by password
0AH
Password error
Communication Protocol