Appendix 3: 610 Series Guide for Rapid Debugging of CNC Machine
Wiring
Parameter setting
Function Code
Name
Set Value
Parameter Description
F0.05
Control mode
2
Open loop current vector control(SVC)
F0.06
Operation command
channel
1
Terminal run command channel
F0.07
Main frequency source A
4
AI2 analog set(DC 0 ~ 10V)
F0.15
Maximum output
frequency
100
Maximum output frequency is 100HZ
F0.16
Upper limit frequency
100
Upper limit frequency is 100HZ
F0.19
Acceleration time 1
3
Acceleration time is 3S
F0.20
Deceleration time 1
3
Deceleration time is 3S
F0.21
Running direction
0
Forward
F2.01
Motor's rate power
-
Set according to actual motor parameter
F2.02
Motor's rate freq.
-
Set according to actual motor parameter
F2.03
Motor's rate speed
-
Set according to actual motor parameter
F2.04
Motor's rate voltage
-
Set according to actual motor parameter
F2.16
Motor tuning
-
0: no action; 1: static tuning;
2: no-load complete tuning
Note: 610 series frequency inverter has been set with the special parameters of CNC machine tools when it leaves
the factory. It only needs to align the system speed; if the actual speed and system speed do not correspond, set
the F0.15 and F0.16 these two parameters.