061
4.1 Function Code
F9 Group - MS and PLC Running, Traverse and Fixed Length Control
Function
Code
Name
Set Range
Minimum
Unit
Factory
Default
Modification
F9.57 Amplitude control
0: fixed amplitude
1: varied amplitude
1
0
×
F9.58 Restart method of traverse
mode
0: start to the state
before stop
1: restart without other
requirement
1
0
×
F9.59 Save traverse state upon
power failure
0: save
1: not save
1
0
×
F9.60 Preset traverse freq.
0.00Hz ~ upper limit
Freq.
0.01Hz
10.00
○
F9.61 Preset traverse freq. hold
time
0.0 ~ 3600.0s
0.1s
0.0
×
F9.62 Traverse amplitude
0.0 ~ 100.0%
0.1%
0.0%
○
F9.63 Step freq.
0.0 ~ 50.0% (of
amplitude)
0.1%
0.0%
○
F9.64 Traverse rising time
0.1 ~ 3600.0s
0.1s
5.0
○
F9.65 Traverse falling time
0.1 ~ 3600.0s
0.1s
5.0
○
F9.66 reserved
—
—
0
◆
F9.67 Length control
0: disabled 1: enabled
1
0
×
F9.68 Preset length
0.000 ~ 65.535(KM)
0.001KM
0.000
○
F9.69 Actual length
0.000 ~ 65.535(KM)
0.001KM
0.000
○
F9.70 Length factor
0.100 ~ 30.000
0.001
1.000
○
F9.71 Length calibration
0.001 ~ 1.000
0.001
1.000
○
F9.72 Shaft circumference
0.10 ~ 100.00CM
0.01CM
10.00
○
F9.73 Pulse per revolution (X7)
1 ~ 65535
1
1024
○
Summary of Contents for SKI600
Page 3: ......
Page 4: ...88888 Operating Instruction Manual High performance Vector Inverter ...
Page 179: ......
Page 180: ......