008
◇
No corrosive gases, vapors, dust or oily dust, no direct sunlight.
◇
No floating dust and metal particle.
◇
Ambient humidity 20% ~ 90% RH.
◇
Vibration less than 5.9m/s
2
(0.6g).
◇
No electromagnetic interference.
◇
Ambient temperature -10℃ ~ 40℃ . Ensure good ventilation when ambient temperature
exceeds 40℃ .
◇
Use electric cabinet or remote control method in non-standard operation environment
and ensure good ventilation and heat dissipation. The service life of VFD lies in installing
environment and operation condition. But even in standard environment, a long-term
continuous running can guarantee a life of no more than 5 years for electrolytic capacitor
and about 3 years for cooling fan. An update or a thorough maintenance in advance is
recommended.
2.1 Operation Environment
To ensure a good cooling cycle, the VFD must be installed vertically, and keep enough space from
surroundings.
2.2 Installing Direction and Space