124
These above function codes defined the
time rising from lower limit to upper limit
of frequency and falling from upper limit
to lower limit. Traverse function applies to
textile and chemical fiber industry, or others
that requires lateral movement or rolling. The
typical application is shown in Fig. F9-6.
The driver accelerates to preset traverse
frequency (P9.60) and stay at it for a period
of time (F9.61). Next,it will arrive at central
frequency within Acc time, and then it will
Fig.F9-6 Traverse Operation
Note:
◇
the central frequency is the frequency of digital
setting, analog setting, impulse, PLC or MS
running.
◇
the traverse is invalid for jog or closed loop
running.
◇
when both PLC and traverse are enabled, the
traverse is invalid when transferring to another
PLC stage. The output frequency begins to traverse
after arriving at the PLC preset frequency within
Acc/Dec time. When receiving stop command,
the driver will stop according to PLC Dec time.
F9.64
Traverse rising time
0.1 ~ 3600.0s
5.0
F9.65
Traverse falling time
0.1 ~ 3600.0s
5.0
Reference value of traverse amplitude is
determined by F9.57. If F9.57=0, traverse
amplitude AW=max.frequency*F9.62; if
F9.57=1, AW=reference*F9.62.
Notice:
1: the traverse frequency is limited by upper and lower
limit of frequency. Improper setting of the frequency
limit will result in faults.
2: the traverse is invalid for jog or PID control mode.
F9.62
Traverse amplitude
0.0 ~ 100.0%
0.0%
This function code indicates the falling
amplitude after reaching upper limit of
frequency, or the rising amplitude after
reaching lower limit of frequency.
If it is set at 0.0%, then there will be no step
frequency.
F9.63
Step frequency
0.0 ~ 50.0% (of traverse
amplitude)
0.0%
'SFR )[
5SBWFSTF"NQMJUVEF"X
"X
B
4UFQ'SFR
"X'
6QQFS-JNJUPG
'SFR'V
-PXFSMJNJUPG
'SFR'-
3VO$PNNBOE
"DDFMFSBUFBDDPSEJOHUP
"DD5JNF
'BMMJOH5JNF
3JTJOH5JNF
%FDFMFSBUF
BDDPSEJOHUP
%FD5JNF
5JNF
4UPQ$PNNBOE
$FOUSBM'SFR'TFU
F9.66
reserved
reserved
0
F9.67
Length control
0 ~ 1
0
4.2 Detailed Function Description
operate according to traverse amplitude
(F9.62), hopping frequency
(F9.63), rise time (F9.64) and fall time
(F9.65) one cycle after another until the stop
command is received. It will then decelerate
to stop within Dec time.
0: disabled
1: enabled