Getting Started
R&S
®
FSW
59
User Manual 1173.9411.02 ─ 43
Together with the bandwidth extension an additional IF output connector is provided
("IF WIDE OUTPUT"). As opposed to the default
tor, the IF output frequency of the optional connector cannot be defined manually, but
is determined automatically depending on the center frequency. For details on the used
frequencies, see the data sheet. The IF WIDE OUTPUT connector is used automati-
cally when the bandwidth extension is activated (i.e. for bandwidths >
80
MHz).
5.2.2.7
Digital I/Q 40G Streaming Output Connector (R&S
FSW-B517)
The Digital I/Q 40G Streaming Output (QSFP+) connector is provided by the hardware
of any bandwidth extension option for 512
MHz or more.
If necessary, remove the metal cover from the connector on the rear panel of the
R&S
FSW.
The output connector provides I/Q data streams with a sample rate of up to 600
MHz, if
the R&S
FSW-B517 option is installed and active.
Output is activated in the software ([INPUT/OUTPUT] key). Currently, it is only suppor-
ted by the I/Q Analyzer application.
See the R&S
FSW I/Q Analyzer and I/Q Input User Manual for details.
5.2.2.8
IF OUT 2
GHz / 5
GHz Connector
The female SMA connector is only available for instrument models
R&S
FSW26/43/50/67/85. It can be used to provide intermediate frequency (IF) output
of approximately 2
GHz at a frequency of 2
GHz.
Output is activated in the software ([INPUT/OUTPUT] key).
Instrument Tour