Remote Commands
R&S
®
FSW
871
User Manual 1173.9411.02 ─ 43
OFF | 0
Switches the function off
ON | 1
Switches the function on
Example:
CALC:LIM:ACP:GAP1:REL:STAT ON
[SENSe:]POWer:ACHannel:BWIDth:GAP<gap>[:AUTO]
<Bandwidth>
[SENSe:]POWer:ACHannel:BANDwidth:GAP<gap>[:AUTO]
<Bandwidth>
This command defines the bandwidth of the MSR gap (CACLR) channel in all sub
block gaps.
This command is for MSR signals only (see
Suffix:
<gap>
.
1 | 2
Gap (CACLR) channel number
Parameters:
<Bandwidth>
numeric value in Hz
*RST:
3.84 MHz
Default unit: Hz
Example:
SENS:POW:ACH:BAND:GAP2 5MHZ
Manual operation:
See
[SENSe:]POWer:ACHannel:FILTer:ALPHa:GAP<gap>[:AUTO]
<Alpha>
This command defines the roll-off factor for the specified gap (CACLR) channel's
weighting filter in all sub block gaps.
Suffix:
<gap>
.
1 | 2
Gap (CACLR) channel number
Parameters:
<Alpha>
Roll-off factor
Range:
0 to 1
*RST:
0.22
Example:
SENS:POW:ACH:FILT:ALPH:GAP2 0.2
Manual operation:
See
[SENSe:]POWer:ACHannel:FILTer[:STATe]:GAP<gap>[:AUTO]
<State>
This command turns the weighting filter for the specified gap (CACLR) channel in all
sub block gaps on and off.
Configuring and Performing Measurements