Chapter 7 Preparing for crane operation
175
Daily function check of safety equipment
Carry out the function check without load and with all extension booms retracted.
Emergency cut-off function check
Danger!
If the crane doesn’t stop after pressing the emergency cut-off button
or if other crane movements are still possible there is acute danger to
life.
Working with a defective emergency cut-off button is grossly negligent. Do not operate the crane and
contact a PALFINGER service partner.
x
Operate any crane function. The crane must move perfectly in all directions.
x
Press the emergency cut-off button while the crane is moving. The crane must come to a stop.
Whenever the emergency cut-off button is pushed, it snaps into the OFF position.
x
Again, operate any crane function.
The crane must not move.
Resuming work with the crane:
x
The reason for pressing the emergency cut-off switch (danger situation) must have been resolved.
x
Release the emergency cut-off button;
In case of remote operation the remote control console can now be restarted.
x
The crane should move perfectly in all directions.
Note!
The emergency cut-off button on the remote control console switches
off the remote control handset.
Summary of Contents for PK 34002-SH P7
Page 1: ......
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 14: ......
Page 24: ......
Page 26: ......
Page 30: ......
Page 66: ...Device and function 60 Overview of labels...
Page 76: ......
Page 78: ......
Page 128: ......
Page 158: ......
Page 182: ......
Page 184: ......
Page 208: ......
Page 210: ......
Page 222: ......
Page 224: ......
Page 242: ......
Page 252: ......
Page 254: ......
Page 258: ......
Page 259: ...Chapter 13 253 C H A P T E R 1 3 Technical description...
Page 260: ...254...