Safety and Health Standards
16
Minimum distances from live lines
Voltage
Minimum distance
up to 1000 Volts
1.0 meter (3.3 feet)
unknown or over 1000 Volts
5.0 meters (16.5 feet)
Actions to take in the event of flashover
Note!
An accident with severe consequences can only be prevented by the
correct response.
x
Stay calm, do not move.
x
Warn persons standing in the vicinity and direct them to observe the safety distance.
Danger!
Upon contact with a live electric line with the ground, a potential
gradient occurs. Within the potential gradient there is acute danger to
life.
x
The minimum distance to the vehicle, device, load or broken power lines is 20 meters / 66 feet
(potential gradient).
x
Leave the danger zone of potential gradient only by jumping with both feet. Keep your legs closed
because of the step voltage.
x
Under no circumstances you should leave the high stand, top seat, driver's cab, truck bed or
workman basket; stay where you are and don't touch anything.
x
Do not touch the device, the load or the broken lines.
x
Immediately arrange the switch-off of the live electric line.
Danger!
Approaching any persons, devices or loads situated inside the electric
circuit creates acute danger to life.
Summary of Contents for PK 34002-SH P7
Page 1: ......
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 14: ......
Page 24: ......
Page 26: ......
Page 30: ......
Page 66: ...Device and function 60 Overview of labels...
Page 76: ......
Page 78: ......
Page 128: ......
Page 158: ......
Page 182: ......
Page 184: ......
Page 208: ......
Page 210: ......
Page 222: ......
Page 224: ......
Page 242: ......
Page 252: ......
Page 254: ......
Page 258: ......
Page 259: ...Chapter 13 253 C H A P T E R 1 3 Technical description...
Page 260: ...254...