Safety equipment
98
Manual lever error:
Gets shown if when the system is started a lever has already
been actuated or any stabilization functions get triggered during
crane operation.
Remedy:
x
Move lever into neutral position.
x
Quit pop-up - if the error persists, contact
PALFINGER service partner.
Sensor signal comparison:
Gets shown if the sensors’ signal values are not the same.
Remedy:
x
Quit pop-up - if the error persists, contact
PALFINGER service partner.
Oil status error:
Gets shown if the oil temperature or fill level is outside the
specified warning limits.
Remedy:
x
Check oil status and depending on display
allow crane to cool down or top up oil.
x
Quit pop-up - if the error persists, contact
PALFINGER service partner.
x
If necessary, retrofit oil cooler.
Console tilted:
Gets shown if the transmitter's maximum tilt sensor gets triggered.
The remote control console has been tilted at too great an angle
or has been dropped. This deactivated the functions of the levers.
Remedy:
x
Turn switch further to START and hold in this
position for about 2 seconds until you hear a
beep.
The operating levers get activated.
Summary of Contents for PK 34002-SH P7
Page 1: ......
Page 2: ......
Page 4: ......
Page 8: ......
Page 12: ......
Page 14: ......
Page 24: ......
Page 26: ......
Page 30: ......
Page 66: ...Device and function 60 Overview of labels...
Page 76: ......
Page 78: ......
Page 128: ......
Page 158: ......
Page 182: ......
Page 184: ......
Page 208: ......
Page 210: ......
Page 222: ......
Page 224: ......
Page 242: ......
Page 252: ......
Page 254: ......
Page 258: ......
Page 259: ...Chapter 13 253 C H A P T E R 1 3 Technical description...
Page 260: ...254...