![background image](http://html1.mh-extra.com/html/omron/scara-r6y-xe-series/scara-r6y-xe-series_maintenance-manual_743985022.webp)
3
Per
iodic inspection
3-2
2. Daily inspection
The following is an inspection list that must be performed every day before and after operating the robot.
■
Inspection to be performed with the controller turned off
Step1
Turn off the controller.
Step2
Place a sign indicating the robot is being adjusted.
Place a sign indicating the robot is being inspected, to keep others from operating the controller switch.
Step3
Perform the daily inspection.
Enter the safety enclosure and check the following points.
Checkpoint
Procedure
Robot cable
User cable and wiring
Check for scratches, dents and excessive bend and kinks. (If the machine
harness or robot cable is damaged, contact your distributor.)
Regulator, joints, air tube,
solenoid valve, air cylinder
Check air pressure.
Check for air leaks.
Check drain.
Check air filter for clogging or damage.
Robot exterior
Check for damage. (If a damage is found, contact your distributor.)
■
Inspection to be performed with the controller turned on
Step1
Turn on the controller.
Check that no one is inside the safety enclosure, and then turn on the controller.
Step2
Place a sign indicating the robot is being adjusted.
Place a sign indicating the robot is being inspected, to keep others from operating the controller,
programming box or operation panel.
Step3
Perform the daily inspection.
Check the following points from outside the safety enclosure.
Checkpoint
Procedure
Safety enclosure
Check if the safety enclosure is in place.
Check if emergency stop is triggered when the door is opened.
Check if warning labels are affixed at the entrance and clearly visible.
Emergency stop device
Press the emergency stop button to check if it works.
Robot movement
Check for abnormal movement and excessive vibration and noise. (If any
abnormal symptom is found, contact your distributor.)
Z-axis brake operation *
Check if the brake works to stop the Z-axis from dropping more than 3mm from
the stationary point. (If any abnormal operation is found, contact your
distributor.)
* Visually check the Z-axis movement when you press the emergency stop button from outside the safety enclosure and
also when you turn off the controller.
■
Adjustment and parts replacement
CAUTION
• After inspection, if you notice any adjustment or parts replacement is needed, first turn off the controller and
then enter the safety enclosure to perform the necessary work. To perform the inspection after the adjustment
and parts replacement work, follow the steps stated in
■
Inspection to be performed with the controller turned
off and
■
Inspection to be performed with the controller turned on described above.
• If repair or parts replacement is required for the robot or controller, please contact your distributor. This work
requires specialized technical knowledge and skill, so do not attempt it by yourself.
Summary of Contents for SCARA R6Y XE Series
Page 1: ...7 6HULHV DW 1R 1 5 VHULHV 0 17 1 1 0 18 6 5 5RERWV VHULHV...
Page 2: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 14: ......
Page 16: ......
Page 20: ......
Page 30: ......
Page 50: ......
Page 90: ......
Page 92: ......
Page 104: ......
Page 108: ......
Page 110: ......
Page 124: ......
Page 135: ...Chapter 10 Robot cable replacement Contents 1 Robot cable replacement 10 1...
Page 136: ......
Page 139: ...Chapter 11 Maintenance parts Contents 1 Consumable parts 11 1 2 Basic specification 11 2...
Page 140: ......
Page 144: ...DW 1R 1 XWKRUL HG LVWULEXWRU 3ULQWHG LQ XURSH...