PART 2: CX-Server PLC Tools
OMRON
CHAPTER 10 – Data Links
CX-Server PLC Tools_ Page 95
Toolbar
(1) (2) (3) (4)
(5) (6) (7) (8) (9) (10) (11)
(12) (13) (14) (15)
(16) (17)
(18)
(19) (20)
No. Icon
Function
(1)
New
Creates new data link tables.
(2)
Show All Network Nodes
Shows all nodes in the network.
(3)
Opens a data link tables, Files with any of the file name
extensions shown below can be opened.
When a file is opened, the proper editor starts up.
Controller Link
.cl2 – CX-Net Controller Link/CLKSS data link tables
.cl3 – CX-Net Controller Link data link tables
.clk – CLKSS data link tables
.csv – CX-Net Controller Link data link tables (tab-delineated
text file)
Open
SYSMAC LINK
.sl3 – SYSMAC LINK data link tables
.slk – SYSMAC LINK data link tables for SYSMAC Support
Software
.csv – SYSMAC LINK data link tables (tab-delineated text
file)
(4)
Save
Saves the data link tables that are being edited.
(5)
Toggle Network/Single Node
Operation
Specifies either all nodes or a single node for data transfers.
(6)
Transfer to PLC
Downloads online data link tables from the computer to a PLC.
(7)
Transfer from PLC
Uploads online data link tables to the computer.
(8)
Delete
Deletes data link tables.
(9)
Verify Node
Compares data link tables generated by CX-Net with data link
tables stored in the PLC. If they do not match, a error dialog box
is displayed.
(10)
Data Link Operation/Status
Displays the operation and data link status of manually set data
links.
(11)
Automatic Data Link Setup
Sets parameters for automatically set data links, and transfers
them to the startup node.
(12)
Validate Table
Checks data link tables.
(13)
Wizard
Executes the Datalink Wizard.
(14)
Add Source Link
Adds a node to the data links.
(15)
Add Destination
Adds the receive area of a participating node to the data links.
(16)
Set Source or Destination
Link Area Properties
Displays the Node Settings dialog box. This dialog box is used
to modify the node properties.
(17)
Delete Link Destination
Service Area
Deletes nodes selected in the Data Link Configuration window,
or deletes a receive area.
(18)
Zoom In/Zoom Out/Zoom
Original
Zooms the Data Link Configuration window in or out, or returns
it to the initial scale.
(19)
Prints data link information.
(20) Help
Displays
help.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......