![background image](http://html1.mh-extra.com/html/omron/cx-programmer-v9/cx-programmer-v9_operation-manual_744204051.webp)
OMRON
PART 1: CX-Programmer
CX-Programmer_Page (xvii)
•
Password Protection of Function Blocks
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The function block properties could be set to
prevent the display of a function block
definition's program.
The following two kinds of password protection can be set.
•
Password protection restricting both reading and writing.
•
Password protection restricting writing only.
Starting the Switch Box Utility with PLC Information
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The Switch Box Utility could be started from
the CX-Programmer’s Tools Menu, but the
PLC model and communications settings
could not be inherited in that case.
The Switch Box Utility can start with the PLC model and
communications settings set in the CX-Programmer’s project.
Saving the CPU Unit’s Error Log as a CSV File
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The CPU Unit’s error log could not be saved.
The CPU Unit’s error log can be saved as a CSV file. The data
collected in these CSV files can be analyzed or printed later with
programs such as MS Excel.
Displaying Current Consumption in the I/O Table Window
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The current consumption for the 5 V system
could not be separated from the 26 V/24 V
system in the I/O table window’s current
consumption display. The total current
consumption at the different voltages could
not be separated. There was no total power
consumption display.
The current consumption display in the I/O table window is divided into
5 V and 26 V/24 V system displays. A total power consumption display
was also added.
Displaying Unit Versions in the I/O Table Window
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The I/O table window’s Unit profile information
display showed only the model number and
did not show the unit version.
The unit version was added to the I/O table window’s Unit profile
information display in addition to the model number.
USB Supported as a Network Type
Previous version (Ver. 6.0)
New version (Ver. 6.1)
USB was not available as a network type.
As part of the CP Series support upgrade, USB is supported as a
network type for the connection between the computer and PLC. This
improvement allows the computer’s USB port to be connected to the
PLC’s USB port. In addition, if the computer supports automatic online
USB connections, this function can be used.
Note: This function can be used only with the CP Series PLCs, which
are equipped with USB port.
CP1H Memory Cassette Transfers and Flash Memory Backup Functions
Previous version (Ver. 6.0)
New version (Ver. 6.1)
The CP1H CPU Units were not supported.
When the PLC model is set to CP Series CP1H, it is possible to
transfer and verify data between a Memory Cassette and the CP1H
CPU Unit. The contents of Data Memory in the CPU Unit’s RAM can
also be backed up to flash memory as initial values. (To access these
functions, select
PLC – Edit – Memory Cassette/DM
.)
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......