OMRON
PART 1: CX-Programmer
CX-Programmer_Page (xxxv)
Version 3.2 Upgrade Information
The following tables outline the changes that have been made from version 3.1 to version 3.2 of the CX-
Programmer.
•
New Models for Automatically Set Data Links
Previous version
(version 3.1)
New version (version 3.2)
With automatically set data links for Controller Link Networks, 1:N allocations are supported
in which data communications are set individually for the master node and slave nodes. (The
models that support this functionality are listed below.)
Any of the following four settings (data link patterns) can be used for automatic data links.
Equality layout (previous method), common type, 1 to 1 type, or chain type
•
CS1W-CLK21-V1
•
3G8F7-CLK21-EV1
•
CS1W-CLK12
-
V1
•
3G8F7-CLK12-EV1
•
CS1W-CLK52-V1
•
3G8F7-CLK52-EV1
Applicable
models:
•
CJ1W-CLK21-V1
With automatically set data
links, all nodes shared the
same data using the common
settings, i.e., the send size for
each node was the same, and
send/receive nodes were
always in the order of node
addresses.
Note: The 1:N allocations for automatic data links cannot be used with any other models.
Refer to the
Controller Link Operation Manual
for details.
Automatic Setting Procedure for Controller Link Networks
1. Go online with the PLC that is to be used as the polling node.
2. Select
Data Link – Setup
from the CX-Net.
If on the local network (i.e., if the network address is 0), select
Controller Link
and click the OK
Button.
The
Data Link
Component
Dialog Box will be displayed.
3. Select
Automatic Datalink Setup
from the
Online
Menu.
Select
Controller Link
and click the
OK
Button.
The
Automatic Datalink
Dialog Box will be displayed.
4. In the
Automatic Datalink Type
Box, select
Equality layout, Common type, 1 to 1 type
, or
Chain
type
and set the automatic data link areas as shown below.
•
Equality Layout (Previous Method)
This is the previous automatic data link type where all nodes are allocated the same sizes of data
links.
Settings Common to All Automatic Data Link Types
A
G
H
1
B
2
6
5
3
D
E
F
C
4
No.
Item
Description of function
A Generation
Type
Select
Automatic
. (If
Manual
is selected, data links will
be run using data link tables set separately.)
B Power
Up
Run State
Select
Start
to automatically start data links when power
is turned ON to the PLC.
C Close Closes
the
Automatic Datalink
Dialog Box.
D
Read
Reads the settings from the PLC.
E
Write
Writes the settings to the PLC.
(If the
Power Up Run State
is set to
Start
, the data links
will start running when the settings are written to the
PLC.)
F Help
Displays
help.
G Automatic
Datalink
Type
Select the type of data links to be automatically set up
from the following.
Equality Layout (Previous method)
Common Type (1:N settings)
1 to 1 Type (1:N settings)
Chain Type (1:N settings)
H
Result
The status is displayed when the Read or Write Button is
clicked.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......