PART 1: CX-Programmer
CHAPTER 3 – Project Reference
OMRON
CX-Programmer _Page 46
4. Enter the text or item to be found in the
Find What
field.
The pull-down list on the
Find What
field can be used to enter the contents used for
previous find operations.
5. Select the search criteria from the available options.
Note:
By deselecting
Include symbol table
, the symbol table can be omitted from a
search and the search range will include the ladder program only. This omits
unnecessary searches of symbol tables, thereby shortening the search time. (CX-
Programmer Ver. 4.0 or later.)
6. Select either the
PLC, Program,
or
Current view
to set the scope of the search. Click
Find Next
to begin the search. This displays the match found, and where in the string the
it was found. The view also changes to where the result is located. Select
Cancel
to abort
the operation.
7. Click
Report
instead to produce a report of all occurrences of the search. Once this
report is generated, shown on the ‘Find Report’ tab of the output window, it is possible to
move to a particular occurrence by double-clicking the report line.
Note:
During a search matches are described by a context descriptor string above the
lower scope box. The information contained in this string will include Step, Operand,
and Step Mnemonic information.
Using Find and Replace
Type of search
The search takes place within programs and symbol tables, depending upon the currently selected item on the
Project Workspace or the currently selected window. If for example the focus is on the Project Workspace when
the search is started then all searchable items within the workspace will be searched in tree order. When the
search is started from a section, or from the tree set at either section or symbol table level then only that item
will be searched. If the search is started at program level then only the local symbol table and the sections
relating to that program level then only the local symbol table and the sections relating to that program are
searched. When the search is started at PLC level then global, local and all sections will be searched. If the
search is started at the project level than all PLCs and their global and local symbol tables and sections will be
searched.
Note that if search is started when the focus is on the I/O Comment view, the search will occur only on this view.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......