PART 2: CX-Server PLC Tools
CHAPTER 8 – CX-Server Network Configuration Tool (CX-Net)
OMRON
CX-Server PLC Tools_Page 88
Creating and Editing a SYSMAC NET Data Link Table Item
Use the following procedure to create SYSMAC NET Data Link Table Item.
1, 2, 3…
1. Select
the
New
button from the toolbar in the SYSMAC NET Data Link Table Editor
dialog.
2. Select
the
Insert Table Item
option from the
Table
menu. Address information can also be
edited by double-clicking on the required node.
The Add SYSMAC NET Data Link Table Item dialog allows the memory area at the node to be configured. Use
the following procedure to configure the node.
1, 2, 3…
1. Enter the node number in the
Node No
field; this must be in the range 1 to 126. /verify
where
2.
Enter the memory size; this must be in the range 0 to 127.
3. Select
the
OK
pushbutton to redisplay the Data Link Table Editor.
Note:
The above example applies to CV-Series, but C-Series operates in exactly the same
manner although the information displayed differs slightly.
To edit a Data Link table, double-click on a table item or select the
Edit Table Item
button
from the toolbar; the Edit Data Link Table dialog is displayed (this is identical to the Add Data
Link Table Item dialog shown above).
Deleting an Item from the SYSMAC NET Data Link Table
Use the following procedure to delete an item from the SYSMAC NET Data Link Table.
1, 2, 3…
1.
Select the node to delete an item and select the
Delete Item
button from the toolbar.
2.
A confirmation dialog is displayed. Select the
Yes
pushbutton to confirm the deletion of
the item. Select the
No
pushbutton to abort the operation.
Opening an Existing SYSMAC NET Data Link Table
Use the following procedure to open an existing SYSMAC NET Data Link Table.
1, 2, 3…
1.
To open a table from disk, select the
Open
button from the toolbar in the Data Link Editor
dialog. A standard File Open dialog is displayed.
2.
Select a file from the Open dialog and select the
Open
pushbutton. The SYSMAC NET
Data Link Table Editor is automatically populated with the contents of the selected file.
Note:
SYSMAC NET Data Link table files are identified by the ‘.SM3’ extension.
Logical Error Checking
The SYSMAC NET Data Link Table Check dialog displays any errors resulting from validation
of the address details entered in the table; it is identical in appearance to the SYSMAC LINK
Data Link Table Check dialog shown earlier and is obtained in the same way.
Old Format Tables
Data Link tables were previously held in ‘.SNT’ and ‘.SN2’ file format. The File Open dialog allows these file
types to be opened in the CX-Net Network Configuration tool. Use the following procedure to open ‘.SNT’ and
‘.SN2’ formatted files.
1, 2, 3…
1. Select
the
Add (old)
option from the
Table
menu in the SYSMAC NET Data Link Table
Editor dialog.
2.
Select a file from the Open dialog and select the
Open
pushbutton.
Table Information
The Data Link Table Information dialog allows the recording of comments against a particular
table and is the same both in operation and appearance, as that for the routing table comments
described earlier.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......