PART 1: CX-Programmer
CX-Programmer_Page (xxvi)
•
Confirming whether a Task (Program) Is Executing or Stopped (CS/CJ-series PLCs Only)
Previous version (Ver. 3.3)
New version (Ver. 4.0)
CS/CJ-series PLCs supported
tasks, but the execution status
could be confirmed for the
whole program only and not
for each task.
The following executing/stopped status is displayed for
every task (see note) in the project space.
Note: Cyclic tasks only. Interrupt tasks not included.
•
Running: Indicated as READY (execution enabled) or
RUN (executing status).
•
Stopped: Indicated as INI (not executing status) or
WAIT (standby status).
This function improves debugging efficiency when
using multiple tasks.
•
Checking Whether the Same Address Is Being Used by Another Task (Program): Cross
Reference Report Function (CS/CJ-series PLCs Only)
Previous version (Ver. 3.3)
New version (Ver. 4.0)
CS/CJ-series PLCs supported
tasks, but they did not check
whether the same address
was being used by another
task (program).
By selecting
Duplicate usage over programs
in the
cross reference report function, a list can be checked
for any bits/words that have been allocated an address
already being used by another task (see note).
This function can be used to easily check whether the
same address is being used by another task
(programmer) when two or more programmers are
creating multiple tasks.
Note: Cyclic tasks only (interrupt tasks not included).
Improvements to Password Protection
•
Password Protection for a Single User-set Task or Multiple Tasks (CS/CJ-series CPU Unit
Ver. 2.0 or later)
Previous version (Ver. 3.3)
New version (Ver. 4.0)
Password protection
(reading/editing prohibited)
could be set.
Password protection (reading/editing prohibited) can be
set for a user-set single task or multiple tasks
(programs).
This function provides security and prevents the loss of
intellectual property for specific tasks (programs).
•
Allowing/Prohibiting Creation of Program Files for File Memory (CS/CJ-series CPU Unit
Ver. 2.0 or Later)
Previous version (Ver. 3.3)
New version (Ver. 4.0)
The user could use file
memory operations to transfer
program files (.OBJ) to a
Memory Card, even if UM
(user memory) read protection
was set with a password.
When a password is registered for the whole user
program or individual tasks, an optional setting can be
selected at the same time to allow/prohibit creation
(backup) of the program file (.OBJ).
This function prevents copying of user programs to
Memory Cards.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......