PART 1: CX-Programmer
OMRON
CHAPTER 4 – Reference
CX-Programmer _Page 79
4. Select the contact or coil to monitor.
5. Select
the
Differential Monitor
button from the toolbar. The Differential Monitor dialog
is displayed.
6. The address associated with the contact or coil selection is displayed in the
Address
field.
Select an
Edge
option.
7. Select
the
Sound
setting to retrieve audio whilst monitoring.
8. Select
the
Start
pushbutton to start monitoring. The
Start
pushbutton becomes a
Stop
pushbutton.
9. Select
the
Stop
pushbutton to cancel monitoring. Select the
Close
pushbutton to exit the
dialog.
10. Select the
Toggle PLC Monitoring
button from the toolbar to stop monitoring.
Instruction Editing
The Edit Instruction dialog allows an instruction to be selected and entered into the Ladder program.
The dialog can be displayed in two forms, either:
simple dialog mode
or
detailed dialog mode
. The default
mode can be set in the
Diagram
tab in the
Options
dialog. To change the
simple dialog mode
to a
detailed
dialog mode
, select
Detail
pushbutton.
Use the following procedure to edit instructions in
simple dialog mode
.
1, 2, 3…
1. Double-click on the instruction field in the Ladder program. The Edit Instruction dialog is
displayed.
2. Enter an instruction, either by name or by number. When a correct number has been
entered (of the correct number of digits for the PLC type), the instruction name is
automatically substituted. To insert an instruction with immediate Refresh properties,
apply an exclamation mark (‘!’) to the beginning of the instruction. To insert a
differentiated instruction, apply a ‘@’ symbol to differentiate up or a ‘%’ symbol to
differentiate down at the beginning of the instruction. When the
Show with comment
dialog
option is selected in the
Options
dialog, a comment dialog will appear after
entering an address or a symbol name.
Note:
Check the
Show with comment dialog
option in the
Diagram
tab of the
Options
dialog to
display a comment dialog. The dialog is displayed after the OK pushbutton is selected
on the
Contact
or
Coil
dialog.
3. Enter operands in the same text box with a space between the instruction and each
operand (see below for more details about entering operands).
4. Select
the
OK
pushbutton to complete the operation. Select the
Cancel
pushbutton to
abort the operation.
Note:
When inputting operands for special instructions using CX-Programmer version 5.0 or higher,
symbols can be filtered using symbol names and I/O comments and displayed in a list. Click the
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......