PART 2: CX-Server PLC Tools
CHAPTER 8 – CX-Server Network Configuration Tool (CX-Net)
OMRON
CX-Server PLC Tools_Page 82
Closing a PLC
The
Open / Project Device
button on the toolbar acts as a toggle switch. To close a device,
simply reselect the
Open / Project Device
button on the toolbar (i.e. when the menu option
shows a tick against it and the toolbar button is depressed).
When the device is closed, the details displayed in the
Connection
part of the CX-Net Network Configuration tool
are removed.
Configuring a PLC’s System Settings
The PLC Setup Component can be selected to define the settings which govern the PLC’s
behavior; for example, connection mode. Select the
Configure PLC System Settings
button
from the toolbar. Refer to
Chapter 4 - PLC Setup Component
for further information.
Alternatively, select PLC Setup from the PLC menu.
Scanning for PLC Connections
A serial scan can be performed which searches all PC COM ports to see if there are any currently attached PLCs
and, if found, what communication settings are being employed by those PLCs. This procedure is useful when the
configuration of the PLCs communication settings (i.e. baud rate) are unknown. Device information from the
results of the scan can then be copied into the CX-Server project, if required. Refer to
Chapter 8 - Dragging
Device Information
into a CX-Server Project.
When the Scan Serial Ports for PLCs dialog is first displayed, it shows the results of the last scan to be performed
until the
Refresh
pushbutton has been clicked. Use the following procedure to scan for PLC connections.
1, 2, 3…
1. Open a CX-Server project by selecting the
Open
button from the toolbar or create a new
project. If required, add a device to the CX-Server project by selecting
Add Device
from the
Project
menu and edit the CX-Server project by selecting the
Edit Project
button from the
toolbar.
2. Select
Scan Serial Ports for PLCs
from the
Project
menu. The Scan Serial Ports for PLCs
dialog is displayed.
3. Select either individual ports or select the
Select All
pushbutton to scan all ports from the
Available Ports
field.
4. Select either individual baud rates or select the
Select All
pushbutton to scan all baud rates
from the
Baud Rates
field.
5. Select either individual cable types or select the
Select All
pushbutton to scan all cable
types from the
Cable types
field.
6. Select
the
Next
pushbutton; the Scan Serial Ports For PLCs dialog starts the scan. The
Status
field indicates the current progress. On completion, all currently connected PLCs are
listed in the
Drag and Drop Device Units
field.
Note:
If changes are made to PLC connections after a scan has been made, select the Refresh
pushbutton to update the displayed list.
Dragging Device Information into a CX-Server Project
The scan operation described in Chapter 8 - Scanning for PLC Connections, picks up device information from the
physically connected serial port devices. Once a scan has been performed, the Scan Serial Ports for PLCs dialog
can remain open alongside the CX-Net Network Configuration tool. Dragging a device or network unit from the
Drag & Drop Device Units
field into the
Project Device
field in the CX-Net Network Configuration tool allows
this device information to be added into the CX-Server project.
Use the following procedure to utilise a convenient shortcut for entering PLC details into a CX-Server project.
1, 2, 3…
1. Open a CX-Server project by selecting the
Open
button from the toolbar or create a new
project. If required, add a device to the CX-Server project by selecting
Add Device
from the
Project
menu and edit the CX-Server project by selecting the
Edit Project
button from the
toolbar.
2. Perform a scan by selecting
Scan Serial Ports for PLCs
from the
Project
menu.
3. Select the required device in the
Drag and Drop Device Units
field.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......