OMRON
PART 1: CX-Programmer
CX-Programmer_Page (xlv)
CX-Net (Network Configuration) Functions
•
CX-Net
Menus Changed
Previous version (Ver. 3.0)
New version (Ver. 3.1)
Unit Status
and
Communications
Unit Setup
were on the
PLC
menu.
Operations for Communication units were separated from those for the PLCs and
Unit Status/Error Log
and
Communications Unit Setup
were moved to the
Network
menu.
Both
Setup
and
Edit
appeared
on the
Routing Tables
and
Data
Link
menus.
Setup
and
Edit
were placed together on a
Setup
menu on the
Routing Tables
and
Data Link
menus.
When
Setup
is selected online, the Routing Table or Data Link Component window
is displayed.
When
Setup
is selected offline, a dialog box with the following selections is
displayed before the Routing Table or Data Link Component window is displayed.
Routing tables: FINS Local, FINS Network, or SYSMAC NET
Data links tables: Controller Link, SYSMAC LINK, SYSMAC NET
Exporting Communications Unit Status and Error Log in CSV Format
Previous version (Ver. 3.0)
New version (Ver. 3.1)
Unit status and the error log can
be monitored in a window but
cannot be saved as files. (The
error log data must be read and
then manipulated manually.)
Unit status and error log data for Communications Units (Controller Link Units and
SYSMAC LINK Units) can be written to files in CSV format.
This allows network errors to be analyzed from CSV files.
Displaying Communications Unit Error Logs for C-series PLCs
Previous version (Ver. 3.0)
New version (Ver. 3.1)
For C-series PLCs, the error log
displayed when
PLC
|
Unit
Status
was selected was the
CPU Unit error log. (A
Communications Unit error log
could not be read or cleared.)
For C-series PLCs, the error log for a Communications Unit (Controller Link Units
and SYSMAC LINK Units) can be displayed and cleared using
PLC
|
Unit
Status/Error Log
.
Save As Operation for CX-Net Projects
Previous version (Ver. 3.0)
New version (Ver. 3.1)
An open project could not be
saved under a new file name.
(The file name could be set only
when a new project was created.
Select
Save As
from the Project menu to save a project open in CX-Net under any
desired name.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......