PART 1: CX-Programmer
OMRON
CHAPTER 3 – Project Reference
CX-Programmer _Page 43
General
The
General
tab provides settings that allow the CX-Programmer environment to be customized.
Use the following procedure to change the environment of CX-Programmer.
1, 2, 3…
1. Select
the
General
tab within the Options dialog.
2. Select
the
IME auto start
option to use 2byte coded characters, if installed.
3. The
Window Environment
options to set the window style when project is created or
opened.
(a) When the
Previous window environment
option is selected, CX-Programmer will
open a project using the settings of last saved.
(b) When the
Show ladder only
option is selected, the project will be opened with only
the ladder view, all the other windows will be hidden.
(c) When the
Show Window
option is selected, a window to show when a project is
opened can be set. The selections of windows are Workspace, Output, Watch, and
Address Reference Tool.
4. Select
Do not normalize rungs at compile for program verification
to prevent
verification errors due to normalization of rungs.
When verifying CX-Programmer project files with programs in the PLC, if redundant
mnemonic codes that were written using the previous support software or CX-
Programmer are present in the PLC, a verification error may occur for the same program
because the CX-Programmer normalizes redundant rungs in the project files when
compiling programs. Select this option to prevent this type of error.
Note:
Normalization deletes redundant rungs from a ladder program and creates the proper
mnemonics.
5. Set the Max. No. of Windows option to limit the number of windows to open.
FB library storage folder:
Set the default folder shown in the Select Function Block Library File Dialog Box (select
the function block, right-click, and select
Insert Function Block – From File
.)
6. Select
the
OK
pushbutton to apply the settings and close the dialog. Select the
Apply
pushbutton to change the settings but remain in the dialog. Select the
Cancel
pushbutton
to abort the operation.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......