![background image](http://html1.mh-extra.com/html/omron/cx-programmer-v9/cx-programmer-v9_operation-manual_744204198.webp)
PART 1: CX-Programmer
OMRON
CHAPTER 6 – Converting a C500/C120/C**P Program to CS/CJ/CP/CVM1 Format
CX-Programmer _Page 115
CHAPTER 6
Converting a C500/C120/C**P Program to CS/CJ/CP/CVM1
Format
This section describes the following functions, their operation, and relevant precautions.
•
Backing up of programs and I/O memory data from C500/C120/C**P PLCs.
•
Restoring data from backup files to C500/C120/C**P PLCs.
•
Verifying programs and I/O memory data between C500/C120/C**P PLCs and backup files.
•
Converting C500/C120/C**P programs and I/O memory data to CS/CJ/CVM1 format.
•
Making host link communications settings for C500/C120/C**P PLCs.
C500/C120/C**P Program Conversion
It is possible to convert C500/C120/C**P programs to CS/CJ/CV-series programs. Also, it is possible to read
programs and DM/HR area data from C500/C120/C**P PLCs to save in a file and write the saved programs and
DM/HR areas data to C500/C120/C**P PLCs.
C500
/
C120/C**P Program Conversion
Programs can be read from C500/C120/C**P and converted to a CXT-format project file to be saved in a file.
The source and destination devices are as follows:
The source: C500/C120/C20/C28/C40/C60P
The destination: CS1G-H/CJ1G-H/CS1H-H/CJ1H-H/CJ1H-H-R/CJ2H/CJ2M/CS1D-S/CS1D-
H/CJ1M/CP1H/CP1L/CP1E/CVM1-V2
Set the following Host Link communications settings and program conversion conditions, and then execute
program conversion.
A backup file (.c5b) is required to execute conversion. Refer to
C500/C120/C**P Program Backup
for
information on how to create backup files.
Host Link Communications Settings
To make the host link communications settings for communications with the C500/C120/C**P, select
Tools –
C500/C120/CxxP Support – Host Link Comms Settings
. The Host Link Comms Settings Dialog Box will be
displayed. Make the Host Link Unit number, COM port settings, and response timeout settings.
The following tables show the Units and Cables that can be connected to C500/C120/C**P.
C500 and C120 PLCs:
Unit
Port on Unit
Port on personal
computer
Network type
(serial
communications
mode)
Model
CPU Unit
Built-in peripheral
port
9-pin, D-sub male
connector
Host Link (SYSWAY)
C200H-IP007 +
CQM1-CIF02
Host Link Unit C500:
C500-LK203/LK201-V1 or
C120-LK201-V1
C120: C120-LK201-V1
RS-232C port,
25-pin, D-sub female
connector
9-pin, D-sub male
connector
Host Link (SYSWAY)
XW2Z-200P-V/
500P-V
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......