PART 1: CX-Programmer
CHAPTER 6 – Converting a C500/C120/C**P Program to CS/CJ/CP/CVM1 Format
OMRON
CX-Programmer _Page 116
C**P:
Unit
Port on Unit
Port on personal computer
Network type (serial
communications
mode)
Model
Host Link Unit
C20-LK201-V1
RS232-C port, 25-pin,
D-sub, female connector
9-pin, D-sub, male connector Host Link (SYSWAY)
XW2Z-200P-V/
500P-V
Change Model
Convert backed-up C500/C120/C**P programs or C500/C120/C**P program files (c5B extension) stored in the
computer.
Select
Tools – C500/C120/CxxP Support – Change Model
to display the Change Model Dialog Box.
The following items can be set in the Change Model Dialog Box.
•
Backup File: Specify the program file to be converted.
•
Target File: Specify a file in which to save the converted program.
•
Conversion range: The program conversion range can be selected from the following.
•
Converts to the END instruction: Converts the program until the first END instruction appears.
•
Converts all program: Converts the program until the last instruction except for NOP appears.
•
Destination PLC/CPU: Specify the conversion destination PLC device.
Saving The Mnemonics Text File Before Conversion:
When converting models, programs prior to conversion can be saved as mnemonics text. Check the
Save the
mnemonics text file before conversion
checkbox and click the
OK
Button in the Change Model Dialog Box.
The program will be saved under the file name
destination file name.txt
in the same folder as the post-
conversion destination file. (If a file with the same name already exists, the mnemonic text file will be saved as a
txt file with the same name with a number added.)
Press the
OK
Button to start program conversion.
The converted project file will be loaded if the conversion process has been completed correctly. If there are
conversion warnings, they will be displayed in annotated comments (comments attached to instructions).
C500/C120/C**P Program Backup
C500/C120/C**P Data Backup
Data from the UM (user program area) and DM/HR areas can be read from C500/C120/C**P PLCs and saved in
a binary backup file (*.c5b). The areas to be saved are as follows.
UM: All
DM0 to DM511
HR0 to HR31
To execute backup, select
PLC – Tools – C500/C120/CxxP Support – Backup
to display the dialog box.
Specify the target file and click the
OK
Button. The file will be backed up.
C500/C120/C**P Data Restore
Data in the UM and DM/HR areas of a C500/C120/C**P backup file (*.c5b) can be written to the UM and
DM/HR areas of the PLC.
To restore files, select
Tools – C500/C120/C**P Support – Restore to PLC
to display the dialog box. Specify
the file to be restored and click the
OK
Button.
Summary of Contents for CX-PROGRAMMER V9
Page 1: ...Cat No W446 E1 12 CX Programmer Ver 9 CXONE AL_C V4 AL_D V4 SYSMAC OPERATION MANUAL...
Page 2: ......
Page 3: ...SYSMAC CX Programmer Ver 9 CXONE AL C V4 AL D V4 Operation Manual Revised July 2010...
Page 4: ......
Page 6: ......
Page 32: ......
Page 33: ...PART 1 CX Programmer...
Page 34: ......
Page 91: ......
Page 111: ......
Page 191: ...PART 1 CX Programmer CHAPTER 4 Reference OMRON CX Programmer _Page 108...
Page 217: ......
Page 233: ......
Page 234: ...PART 2 CX Server PLC Tools...
Page 235: ......
Page 243: ......
Page 249: ......
Page 261: ...PART 2 CX Server PLC Tools CHAPTER 2 PLC Memory Component OMRON CX Server PLC Tools_Page 18...
Page 280: ......
Page 333: ......
Page 377: ......
Page 409: ......
Page 430: ......
Page 431: ...PART 3 CX Server Runtime...
Page 432: ......
Page 476: ......
Page 482: ......
Page 498: ......
Page 524: ......
Page 534: ......
Page 535: ......
Page 536: ......